Products Directory > Electronics & Electrical > Electrical & Electronics >
Lightning Protection System
![]()
Products - 21
|
Lightning Protection System |
Displaying 1-15 of Total 21 Products Found |
-
Products
- Description
- Supplier Information

Our zonal lighting systems have been designed in such a way that they wait for the lightning to strike one of the rods to get grounded. Due to the velocity and undefined path, safety provided by this system is highly effective and reliable. It is synchronizable and can be remotely monitored by a hand held device. This system has 99 % reliability factor and efficiency.
![]()

Zonal Lighting system are used to protect the house from the thunderous and disastrous effects of lightning. Lighting protection system provides a means for controlling it and preventing damage by providing a low resistance path for the discharge of lightning energy. One needs to be very careful while designing a lighting control system as a wrong one may cause more damage to the building. These days, rods are used on the top of the buildings that are connected to the faraday cage to the ground. Such systems wait for the lightning to strike one of the rods to get grounded. Due to the velocity and undefined path, safety provided by this system is ineffective and Unreliable. Lightning is supposed to strike at buildings and other things like, such as a tree touching a high tension power line), thus producing very high voltages which has very bad effect on property such as following underground tree roots, metal porch railings, and copper or steel building water pipes. modern lightning more...
![]()

We offer all the material related to Earthing Material And Lightning Protection System that can be manufactured as per clients' specifications. These products can protect from electic shocks and are safe to use. Our range of Earthing Material And Lightning Protection System includes;
more...
![]()

Our copper earthing system has low electrical resistance. It has good corrosion resistance and can easily carry high currents repeatedly. Manufactured using solid copper or stainless steel with copper bonding, they are low in cost and proves as a permanent grounding solution for safety of human, livestock, equipment and property.
![]()

Lightning is actually a visible discharge of static electricity within a cloud and also between clouds. The light protection system offered by us provides a means by which this discharge might leave or enter the Earth without actually passing through the damaging non-conducting parts of a structure, like those made of wood, brick, tile of- concrete. Such a lightning protection system does not prevent lightning from striking but provides a means for controlling it and preventing damage by providing a low resistance path for the discharge of lightning energy.
The Lightning Protection System has undergone many changes and today's lightning protection system exhibit the best in terms of design, materials and installation, thus valuable life and property can be well protected from nature's hazardous and exciting phenomenons like, lightning. Lightning is a unique form of energy and an expert can only install proper protection systems against it.
![]()

Our lighting protection system is manufactured using superior quality copper alloy. It includes:
Multiple Point
MTL : It is is an electrolytic copper multiple point which is used with elevation rod.
Ridge Saddle
MTL : Gunmetal / Brass is used for supporting lightning conductor air terminals on ridges.
![]()

Our range of earthing & lightning in protection system successfully meets the requirement of the telecom and other allied industries. Some of the specifications of our products are: more...
- Telecom Consultants & Construction Co.
![]()

Our range of Home protectors provides premium power protection for home personal computers and sensitive electronic equipments like home theater systems, telephones, and laser printers. Our product includes sliding safety covers, and a detachable cord-management clip, which helps in organizing cables.
- Crystal Corporation,Akurdi
![]()

We offer protection and control devices to cater to the varied industrial applications. Under this category, we offer:
AC Protection Systems
Battery Protection Systems
Lightening Protection Systems
Surge Protection Systems
Auto-Phase Selector
Room Temperature Controllers
Servo Voltage Stabilizers- Univision Power Systems
![]()

PowerTrip Transient Voltage Surge Suppression Devices (TVSS) are available in complete range for protection on Power, Data and Telephone lines. Power line protection devices are available both in Box mountings and Din Rail mounting. The box mounting devices are integrated Class B & C protectors having complete four route protections i.e., L_L, L_N, L_E and N_E. The Din Rail products have replaceable module facility.
- Alltec Protection System (P) Limited
![]()

We ensure adequate protection of any Telecom / Civil sites against the threat of lightning and transients voltages. External protection against direct lightning with the use of ESE or Terrastat (USA) terminals which are capable to work in all whether conditions and handling multiple strike of lightning in the order of 200kA of 10 / 350 micro seconds wave forms.
The class A protection to power root to ensure with the installation of our lightning protection unit. Our Surge arresters are UL, IEC61643, VDE0675 complied of DHEN+SOHNE, Germany. These are CACT Approved and RDSO recommended. Capacity design using fuseless lightning arrestors operating on RADAX Flow Technology in shunt line to neutral and neutral to earth. Surge protection unit (class C protection) before the equipment is capable of handling surge of the order 40kA, 8/20 micro seconds using fuseless surge arrestors.- Pragati Electrocom Private Limited
![]()

The Exothermic Weld connection is a molecular weld which becomes an integral part of the conductor. It is highly dependable non-corrosive and damage free to an external pressure. At times it has better current capacity than the conductor due to increased surface area.
The system is very field friendly since it is light and portable, required no external power source. It requires very little skill/time to achieve good maintenance free weld joint.- Alltec Protection System (P) Limited
![]()

TerraEval Advanced Solution Assessment provides customized lightning protection and grounding designs and specifications complying to IEEE standards: 80, 81, 142, and 1100; UL96A; NFPA 780; API2003; BS6651; UNE 21186; and NFC 17102.
Soil resistivity and ground system impedance testing
Validated model utilization to perform evaluation of step/touch potential, conductor size, fault current analysis, maximum ground potential rise, and assessment of lightning shielding system
Recommendations for grounding system upgrades, enhancing lightning shielding, and surge protection- Alltec Protection System (P) Limited
![]()

Environmentally friendly backfill TerraFill provides efficient long lasting and maintenance free earth pits even when used with conventional earthing electrodes of Copper, G.I. or Copper Cladded material in any shape or size. It helps in improving the system efficiency up to 63% from normal conditions of operation. They have a capacity to absorb and retain water 13 times its dry weight, save the electrode from corrosion, does not allow system degradation even in extreme temperature.
- Alltec Protection System (P) Limited
![]()

The TerraDyne Electrolytic Grounding System is a multipurpose Maintenance Free Long life Stable Grounding system. It is designed to provide an earth reference point with lowest possible ohm value independent of soil type, moisture content, soil temperature and frequency short circuit currents. Long-term protection from lightning, electrical transients, static discharges, electro- magnetic interference, and other electrical hazards. This system may be used in any type of soil condition for virtually any application where the protection of machinery, electronics, and personnel is important. Some of the many applications where it is commonly used include cellular, broadcasting, computer facilities, power substations, medical facilities and industrial sites. TerraDyne Electrolytic Grounding Systems are guaranteed for 30 years stable and maintenance free operations, with an expected life of 50 years.
- Alltec Protection System (P) Limited
![]()
